category: pluggable terminal block
item | data | ||
approval | |||
test standard | iec61984 / ul1059 | ||
pitch[mm] | 5.08 | ||
poles | 2-24p | ||
iec61984 test data | vde certificate no. 40022408 | ||
rated voltage[v] | 320 | ||
rated current[a] | 20 | ||
rated connection capacity(solid/stranded) [mm²] | 2.5 | ||
surge voltage category/pollution degree/material group | iii/2/i | ||
rated impulse voltage[kv] | 4 | ||
rated torque[n·m] | 0.4 | ||
ul1059test data | ul file number e228872 | ||
use group | b | c | d |
rated voltage[v] | 300 | / | 300 |
rated current[a] | 10 | / | 10 |
(rated connection capacity) (solid/stranded) [awg] | 28-dec | ||
rated torque[lb. in] | 3.54 | ||
general data | / | ||
screw | m2.5 | ||
inflammability classul94 | v-0 | ||
ambient temperature[℃] | -40~+105 | ||
relative humidity | 5%-95% | ||
inspection standard | mil-std-105e ii | ||
aql | 0.65 | ||
warranty | 12 months | ||
material and plating | / | ||
housing | pa66,ul94v-0 | ||
screws | steel,zn plated | ||
contact | copper alloy,sn plated | ||
cage | copper alloy,ni plated | ||
wire connecting | |||
7-8mm; recommended stripping length 7-8mm; | |||
1.)for solid wire, stripping wire to the appointed length, then tightening with rated torque. | |||
2.)for stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque. | |||
tightening process should be steady, can’t use explosive force. |