category: pcb universal screw terminal block
item | data | ||
approval | |||
test standard | iec60947-7-4/ul1059 | ||
pitch [mm] | 6.35 | ||
pole | 01-xxp | ||
iec60947-7-4 test data | / | ||
rated voltage [v] | 320 | ||
rated current [a] | 41 | ||
rated connection capacity)(solid/stranded [mm2] | 0.5-6 | ||
surge voltage category/pollution degree/material group | iii/2/i | ||
rated impulse voltage [kv] | 4 | ||
rated torque [n.m] | 0.5 | ||
ul1059test data | ul1059 | ||
use group | b | c | d |
rated voltage [v] | 300 | / | 300 |
rated current [a] | 30 | / | 10 |
rated connection capacity solid/stranded [awg] | 26-oct | ||
rated torque [lb. in] | 4.43 | ||
general data | / | ||
screw | m3 | ||
inflammability classul94 | v-0 | ||
ambient temperature [℃] | -40~+105 | ||
relative humidity | 5%-95% | ||
inspection standard | mil-std-105e ii | ||
aql | 0.65 | ||
warranty | 12 months | ||
material and plating | / | ||
housing | pa66 | ||
screws | steel,zn plated | ||
contact | copper alloy,sn plated | ||
cage | steel,zn plated | ||
wire connecting | |||
3-14mm; recommended stripping length 13-14mm; | |||
1.)for solid wire, stripping wire to the appointed length ,press button and insert the wire. | |||
2.)for stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque. | |||
tightening process should be steady, can’t use explosive force.) |