category: pluggable terminal block
item | data | |||
|
||||
test standard | iec/en61984:2009 / ul1059 | |||
pitch [mm] | 7.5 | |||
poles | 2-12p | |||
en61984 test data | / | |||
rated voltage [v] | 400 | |||
rated current [a] | 20 | |||
rated connection capacity (solid/stranded) [mm²] | 0.2-2.5 | |||
(surge voltage category/pollution degree/material group) | iii/3/i | |||
rated impulse voltage [kv] | 4 | |||
rated torque [n·m] | / | |||
ul1059test data | ul file number e228872 | |||
use group | b | c | d | |
rated voltage [v] | 300 | 300 | 300 | |
rated current [a] | 15 | 15 | 10 | |
rated connection capacity (solid/stranded) [awg] | 22-14 | |||
rated torque [lb. in] | / | |||
general data | / | |||
screw | / | |||
inflammability class ul94 | v-0 | |||
ambient temperature [℃] | -40~+105 | |||
relative humidity | 5%-95% | |||
inspection standard | mil-std-105e ii | |||
aql | 0.65 | |||
warranty | 12 months | |||
material and plating | / | |||
housing | pa66 | |||
contact | copper alloy,sn plated | |||
recommended stripping length 9-10mm; | ||||
1.)for solid wire: after stripping corresponds to the length of the wire , put the wire into the hole after using the accessory depress the cage spring . | ||||
2.)for strand wire :after stripping corresponds to the length of the wire, can be directly connected or use of the corresponding standard insulated ferrule , then put the wire into the hole after using the accessory press the cage spring. |