category: heavy duty connector
item | data |
inserts | matchingd24b hoods&housings |
approval | ul.csa.vde.ce.cqc |
test standard | din en61 984 / ul1977 |
poles | 4/8p+pe |
the need for additional or dering crimp contacts) | 否 |
no | |
en61984 test data | / |
rated voltage [v] | 400/400 |
rated current [a] | 80/16 |
pollution degree | 3 |
rated impulse voltage [kv] | 6-jun |
insulation resistance | ≥1010ω |
ul/csarated current [v] | 600/600 |
material | polycarbonate |
inflammability class(ul94) | v-0 |
ambient temperature [℃] | -40~+125 |
mechanical working life(mating cycles) | ≥500 |
contacts | |
material | copper alloy |
surface | hard-silver plated |
contact resistance | power area ≤0.3mω |
signal area ≤1mω | |
terminal | screw terminal |
power area screw terminal tightening | 1.5 2.5 4 6 10 16( mm²) |
1.2 2 3 3 3 3 [n·m] | |
signal area screw terminal tightening | 0.5 [n·m] |
power area connection capacity(solid/stranded) | 1.5-16mm² (awg16-6) |
signal area connection capacity(solid/stranded) | 0.5-2.5mm² (awg20-14) |
screw | m6/m3, (steel,ni plated ) |
wire connecting | |
recommended stripping length/power area14mm/signal area 7.5mm | |
for solid wire, stripping wire to the appointed length, then tightening with rated torque. | |
for stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque. | |
tightening process should be steady, can’t use explosive force. |