• 0.02% basic dc accuracy
• large display with 50,000 counts
• dual display for double indication for ac and dc, v and hz, etc.
• true-rms measurements ac and ac+dc
• wide ac frequency bandwidth from 10hz to 100khz
• true-rms or mean value detection mode can be selected
• fast peak hold response time of 250µs
• low-pass filter for motor drive measurements
• low power ω for resistance measurements on sensible electronic circuits by a low and safe test current
• user calibration function
safety design for industrial use
• complies with iec 61010-1 cat iv 600v, cat iii 1000v
• terminal shutter to prevent incorrect test leads' insertion in current terminals
• very wide operating temperature range from -20 to 55ºc
reliable support for data management
• large data internal memory
kew 1062: 10,000 data (logging), 100 data (manual)
• download data and live monitoring on a pc via the usb interface
(option for usb communication set)
* max 32,767 data can be transferred.