fluke 1587/1577 insulation multimeter


category: digital multimeter

quick overview:

tag:#digital multimeter#fluke

share: messenger


consult the features included on the two new insulation multimeters in the comparison chart below to help select the best tool for your application:

feature 1587 1577
insulation test voltages 50v, 100v, 250v, 500v, 1000v
insulation test voltages 500v, 1000v
insulation test: 0.01 mω to 2.0 gω
insulation test: 0.1 mω to 600 mω
auto discharge of capacitive voltage
insulation test smoothing reading
frequency
capacitance
diode test
temperature
min/max
low pass filter (for work on vsd's)
ac/dc voltage
dc millivolts
ac/dc milliamps
resistance (0.1 ω to 50 mω)
continuity
three-year warranty
remote probe, test leads, alligator clips
k-type thermocouple
rugged, utility hard case
auto power off to save battery power
true-rms
large display with backlight
live circuit detection prevents insulation test if voltage > 30 v is detected for added user protection
cat iii 1000v, cat iv 600v measurement category
accepts optional fluke tpaktmmagnetic hanging system to free your hands for other work





















































specifications
voltage dc
maximum voltage: 1000 v
accuracy: 1577: ±(0.2%+2)
1587: ±(0.09%+2)
maximum resolution: 0.001v
voltage ac
maximum voltage: 1000 v
accuracy: 1577: ±(2%+3)
1587: ±(2%+3)
ac bandwidth: 1587: 5khz*
*with low pass filter; 3db @ 800 hz
maximum resolution: 0.1 mv
current dc
maximum amps: 400ma
amps accuracy: 1577: ±(1.0%+2)
1587: ±(0.2%+2)
maximum resolution: 0.01 ma
current ac
maximum amps: 400ma
amps accuracy: 1577: ±(2.0%+2)*
1587: ±(1.5%+2)*
* 1khz bandwidth
maximum resolution: 0.01 ma
resistance
maximum resistance: 50 mω
accuracy: 1577: ±(1.2%+2)
1587: ±(0.9%+2)
maximum resolution: 0.1ω
capacitance(1587 only)
maximum capacitance: 9,999 µf
accuracy: ±(1.2%+2)
maximum resolution: 1 nf
frequency (1587 only)
maximum frequency: 100 khz
accuracy: ±(0.1%+1)
maximum resolution: 0.01 hz
temperature measurement (1587 only)
-40.0 °c to 537 °c
-40.0 °f to 998 °f
excluding probe
diode test (1587 only)
range: 6 v
resolution: 1 mv
accuracy: ±(2 % + 1)

insulation test
minimum test current @ 1kω/v:
1ma
test voltages:
1577: 500, 1000 v
1587: 50, 100, 250, 500, 1000 v
maximum resistance per test voltage:
50v:
100v:
250v:
500v:
1000v: 1577: 600 mω
1587: 2 gω
maximum resolution per test voltage:
50v: 0.01 mω
100v: 0.01 mω
250v: 0.1 mω
500v: 0.1 mω
1000v: 0.1 mω
accuracy per test voltage:
50v: ±(3 % + 5)
100v: ±(3 % + 5)
250v: ±(1.5 % + 5)
500v: 1577: ±(2.0 % + 5)
1587: ±(1.5 % + 5)
1000v: 1577: ±(2.0 % + 5)
1587: ±(1.5 % + 5) to 600 mω, ±(10 % + 3) above 600 mω

environmental specifications
operating temperature
–20 °c to +55 °c
storage temperature
-40°c to +60°c
humidity (without condensation)
0% - 95% (10 °c – 30 °c)
0% - 75% (30 °c – 40 °c)
0% - 40% (40 °c – 55 °c)
operating altitude
2000 m

safety specifications
overvoltage category
complies with ansi/isa 82.02.01 (61010-1) 2004, can/csa-c22.2 no. 61010-1-04, and iec/en 61010-1 2nd edition for measurement cat iii 1000 v and cat iv 600 v
agency approvals
2000 m cat iii 1000 v, cat iv 600 v; 3000 m cat ii 1000 v, cat iii 600 v

mechanical & general specifications
size
203 x 100 x 50 mm (with holster)
weight
624 g
warranty
3 years
battery life alkaline
meter use: 1000 hours
insulation test use: meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. these are standard tests of 1000 v into 1 mω with a duty cycle of 5 seconds on and 25 seconds off.
ip rating
ip40




[download datasheet]

sorry, currently no video uploaded.
sorry, currently no file uploaded.

fluke 1587/1577 insulation multimeter


please leave your product enquiry here. we will get back to you soon.

product specifications

  • product sku : -
  • weight (gram) : -
  • dimension : -