category: din rail terminal block
item | data | |||
approval | ||||
|
||||
test standard | iec/en60947-7-2:2009 / ul1059 | |||
pitch [mm] | 15.2 | |||
poles | 01p | |||
en60947 test data | / | |||
rated voltage [v] | / | |||
rated current [a] | / | |||
rated connection capacity(solid/stranded) [mm²] | 35 | |||
surge voltage category/pollution degree/material group | iii/3/i | |||
rated impulse voltage [kv] | 8 | |||
rated torque [n.m] | 2.5 | |||
ul1059test data | / | |||
use group | b | c | d | |
rated voltage [v] | / | / | / | |
rated current [a] | / | / | / | |
rated connection capacity (solid/stranded) [awg] | 18-0 | |||
rated torque [lb. in] | 22.15 | |||
general data | / | |||
screw | m6 | |||
inflammability class ul94 | v-0 | |||
ambient temperature [℃] | -40~+105 | |||
relative humidity | 5%-95% | |||
inspection standard | mil-std-105e ii | |||
aql | 0.65 | |||
warranty | 12 months | |||
material and plating | / | |||
housing | pa66 | |||
screws | copper alloy,ni plated | |||
contact | copper alloy,ni plated | |||
cage | copper alloy,ni plated | |||
wire connecting | ||||
recommended stripping length14-15mm; | ||||
for solid wire, stripping wire to the appointed length, then tightening with rated torque. | ||||
for stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque. | ||||
tightening process should be steady, can’t use explosive force. |